Description
It is an ultra-low-power miniature digital gas sensor that can detect a wide range of volatile organic compounds (TVOCs), including equivalent carbon dioxide (eCO2) and metal oxide (MOX) levels
KEYESTUDIO CCS811 carbon dioxide, temperature air quality sensor mainly uses the CCS811B chip
Equivalent carbon dioxide (eCO2) is measured in the range of 400 to 8192 ppm (parts per million), and various volatile organic compounds (TVOC) ranges from 0 to 1187 ppb (parts per billion)
At the same time, the sensor comes with a 10K precision 1% NTC thermistor, which can be used to test the specific temperature in the environment
Technical parameters:
Working voltage: DC 5V.
Working current: 30 mA.
Maximum power: 46 mW.
eCO2 measuring range: 400-8192 ppm
TVOC measuring range: 0 to 1187 ppb
Working temperature: -25 ~ +65 °C.
Interface: 7-pin (2.54mm pitch)
Positioning hole diameter: 3 mm.
Dimensions: 36 mm x 20 mm x 7 mm.
Environmental attributes: ROHS
Pinout:
GND - Soil.
VCC - input power (5V).
SDA - I2C data pin
SCL - I2C Tactile Pen
RST - Pin reset: connect to ground, sensor is reset automatically.
WAKE - The WAKE pin should be connected to earth for convenient communication with the sensor.
INT - This is the interrupt output pin that detects when a new reading is ready or the measurement value becomes too high or too low.
KEYESTUDIO CCS811 carbon dioxide, temperature air quality sensor mainly uses the CCS811B chip
Equivalent carbon dioxide (eCO2) is measured in the range of 400 to 8192 ppm (parts per million), and various volatile organic compounds (TVOC) ranges from 0 to 1187 ppb (parts per billion)
At the same time, the sensor comes with a 10K precision 1% NTC thermistor, which can be used to test the specific temperature in the environment
Technical parameters:
Working voltage: DC 5V.
Working current: 30 mA.
Maximum power: 46 mW.
eCO2 measuring range: 400-8192 ppm
TVOC measuring range: 0 to 1187 ppb
Working temperature: -25 ~ +65 °C.
Interface: 7-pin (2.54mm pitch)
Positioning hole diameter: 3 mm.
Dimensions: 36 mm x 20 mm x 7 mm.
Environmental attributes: ROHS
Pinout:
GND - Soil.
VCC - input power (5V).
SDA - I2C data pin
SCL - I2C Tactile Pen
RST - Pin reset: connect to ground, sensor is reset automatically.
WAKE - The WAKE pin should be connected to earth for convenient communication with the sensor.
INT - This is the interrupt output pin that detects when a new reading is ready or the measurement value becomes too high or too low.
Additional Information
Shipping & Return
Reviews ( 0 )
Wishlist
Wishlist is empty.
Compare
Shopping cart